AK1004

Glass pH Electrode (with ATC)

Refillable glass pH electrode for laboratory applications, with BNC connector and 1 m cable.

AK1004 Glass pH Electrode (with ATC)
0 to 90 °CTemperature Range

Overview

The AK1004 is a refillable combined glass pH electrode with a ceramic junction, built for accurate laboratory measurements. The refillable reference lets you top up the electrolyte to maintain a stable junction potential and extend working life, while the ceramic junction suits clear aqueous samples and general laboratory use.

Key features

  • Refillable combined glass pH electrode
  • Ceramic junction for clear aqueous laboratory samples
  • Refillable reference for stable readings and longer life
  • BNC connector with 1 m cable
  • Standard electrode for the AK130 bench meter; compatible with AKSO pH meters

In detail

Supplied as the standard electrode with the AK130 bench meter and available separately, it connects via a BNC plug on a 1 metre cable and works with AKSO pH meters.

Specifications

Measurement Specifications
Parameter Range Resolution Accuracy
Temperature 0 to 90 °C — —
General Specifications
Junction Ceramic
Reference electrolyte Ag/AgCl
Connectors BNC
Body Material Glass
Weight 65 g
Cable length 1 m

Maintaining your pH electrode

Regular cleaning ensures measurement accuracy and extends electrode life. Follow this procedure periodically.

  1. 1

    Prepare a small beaker with electrode cleaning solution (pepsin).

  2. 2

    Remove the electrode protection and immerse the tip in the solution for 20–25 minutes.

  3. 3

    Remove the electrode from the solution and rinse it with distilled or deionized water before and after each procedure.

  4. 4

    Always remove excess water with a soft towel or cloth, without rubbing the bulb.

  5. 5

    Check for air bubbles in the sensing bulb. If present, gently shake the electrode vertically to remove them.

  6. 6

    Store the electrode in AKSO 3M KCl (potassium chloride) solution for 1 hour.

  7. 7

    The electrode is now ready for adjustment — always use fresh calibration solutions.

Important

  • Never leave the electrode in cleaning solution for more than 30 minutes
  • Never use abrasives (brushes, rough paper, etc.) to clean the electrode
  • Do not use aggressive solvents, such as acetone or carbon tetrachloride. To remove oil or grease residues, use a mild detergent and rinse thoroughly.

Find the right instrument
for your application.

Tell us what you measure and where. Our team will recommend the right instrument and configure your complete kit.

Expert consultation

Speak directly with application engineers

Custom kit configuration

Instrument, probe, solutions, and carrying case

Global shipping

Direct or through authorized distributors