AK1001

pH Electrode for Liquids, Polycarbonate Body (with ATC) - BNC/RCA

AK1001 – pH electrode with ATC for accurate measurement in liquids, BNC/RCA connection

AK1001 pH Electrode for Liquids, Polycarbonate Body (with ATC) - BNC/RCA
0 to 14 pHpH Range

Overview

The AK1001 is a combined pH and temperature electrode for general-purpose measurements in water and wastewater treatment, education and routine laboratory work. The glass sensing bulb delivers stable, repeatable pH readings, while the integrated temperature sensor lets compatible meters apply automatic temperature compensation.

Key features

  • Combined pH and temperature electrode
  • Glass sensing bulb for general-purpose use
  • Integrated temperature sensor for automatic temperature compensation
  • BNC/RCA connector with 1 m cable
  • Compatible with AKSO portable and bench pH meters

In detail

It connects through a BNC/RCA plug on a 1 meter cable and is compatible with AKSO portable and benchtop pH meters.

Specifications

Measurement Specifications
Parameter Range Resolution Accuracy
pH 0 to 14 pH — —
Temperature 0 to 50 °C — —
General Specifications
Connectors BNC (pH) / RCA (Temperature)
Cable length 1 m
Body Material PC - Polycarbonate
Junction Single, Teflon
Reference electrolyte 3.3 M KCl, gel
Internal reference Ag/AgCl
Dimensions 160 x 12 mm (Ø)
Weight 60g

Maintaining your pH electrode

Regular cleaning ensures measurement accuracy and extends electrode life. Follow this procedure periodically.

  1. 1

    Prepare a small beaker with electrode cleaning solution (pepsin).

  2. 2

    Remove the electrode protection and immerse the tip in the solution for 20–25 minutes.

  3. 3

    Remove the electrode from the solution and rinse it with distilled or deionized water before and after each procedure.

  4. 4

    Always remove excess water with a soft towel or cloth, without rubbing the bulb.

  5. 5

    Check for air bubbles in the sensing bulb. If present, gently shake the electrode vertically to remove them.

  6. 6

    Store the electrode in AKSO 3M KCl (potassium chloride) solution for 1 hour.

  7. 7

    The electrode is now ready for adjustment — always use fresh calibration solutions.

Important

  • Never leave the electrode in cleaning solution for more than 30 minutes
  • Never use abrasives (brushes, rough paper, etc.) to clean the electrode
  • Do not use aggressive solvents, such as acetone or carbon tetrachloride. To remove oil or grease residues, use a mild detergent and rinse thoroughly.

Find the right instrument
for your application.

Tell us what you measure and where. Our team will recommend the right instrument and configure your complete kit.

Expert consultation

Speak directly with application engineers

Custom kit configuration

Instrument, probe, solutions, and carrying case

Global shipping

Direct or through authorized distributors